| RLNK-415R | RLNK-420R | RLNK-915R | RLNK-920R |
|---|
| Line Voltage | Nominal: 120VAC / Min: 80VAC / Max: 140VAC | Nominal: 120VAC / Min: 80VAC / Max: 140VAC | Nominal: 120VAC / Min: 80VAC / Max: 140VAC | Nominal: 120VAC / Min: 80VAC / Max: 140VAC |
|---|
| Maximum Peak Load | 15A | 20A | 15A | 20A |
|---|
| Maximum Continuous Load | 12A | 16A | 12A | 16A |
|---|
| No Load Power Dissipation | Less Than 1W (Ethernet disconnected, all relays off) | Less Than 1W (Ethernet disconnected, all relays off) | Less Than 1W (Ethernet disconnected, all relays off) | Less Than 1W (Ethernet disconnected, all relays off) |
|---|
| Peak Impulse Current (8/20uS Waveform) | - 12,000 Amps, one time, 9,000 Amps, two times within 5 minutes - Maximum peak impulse current pulse as defined between line and neutral - Maximum multiple impulse current derated per spec | - 12,000 Amps, one time, 9,000 Amps, two times within 5 minutes - Maximum peak impulse current pulse as defined between line and neutral - Maximum multiple impulse current derated per spec | - 12,000 Amps, one time, 9,000 Amps, two times within 5 minutes - Maximum peak impulse current pulse as defined between line and neutral - Maximum multiple impulse current derated per spec | - 12,000 Amps, one time, 9,000 Amps, two times within 5 minutes - Maximum peak impulse current pulse as defined between line and neutral - Maximum multiple impulse current derated per spec |
|---|
| Protection Mode | Line to Neutral only; no ground contamination | Line to Neutral only; no ground contamination | Line to Neutral only; no ground contamination | Line to Neutral only; no ground contamination |
|---|
| Response Time | Less than 1 nanosecond | Less than 1 nanosecond | Less than 1 nanosecond | Less than 1 nanosecond |
|---|
| Surge Energy Dissipation | 120 Joules (10/100 microseconds) | 120 Joules (10/100 microseconds) | 120 Joules (10/100 microseconds) | 120 Joules (10/100 microseconds) |
|---|
| EMI/RF Suppression | >20dB Calculated Line to Neutral - 100kHz to 1Mhz | >20dB Calculated Line to Neutral - 100kHz to 1Mhz | >20dB Calculated Line to Neutral - 100kHz to 1Mhz | >20dB Calculated Line to Neutral - 100kHz to 1Mhz |
|---|